Scientific Reports volume 13, Article number: 10921 (2023) Cite this article

431 Accesses

Metrics details

The present study compared the thickness and gap width of thermoformed and 3D-printed clear aligners (CAs) using micro-computed tomography (micro-CT) and evaluated their translucency using spectrophotometer. Four groups of CAs were tested: thermoformed with polyethylene terephthalate glycol (TS) or copolyester-elastomer combination (TM), and 3D-printed TC-85 cleaned with alcohol (PA) or with centrifuge (PC). CIELab coordinates were measured (n = 10) to evaluate translucency. CAs (n = 10) were fitted onto respective models and micro-CT was performed to evaluate the thickness and gap width. Thickness and gap width were measured for different tooth type and location in sagittal sections on all sides. The PC group showed significantly higher translucency than the PA group, which was similar to the TS and TM groups (p < 0.01). After the manufacturing process, thickness reduction was observed in the thermoformed groups, whereas thickness increase was observed in the 3D printed-groups. The TM group showed the least gap width amongst the groups (p < 0.01). Thermoformed and 3D-printed CAs had significantly varied thicknesses and regions of best fit depending on the tooth type and location. Differences in the translucency and thickness of the 3D-printed CAs were observed depending on the cleaning methods.

Clear aligners (CAs) need to exert a continuous and controlled force on teeth to achieve the desired tooth movement1. They are produced from a variety of thermoplastic materials, including polyethylene terephthalate glycol (PETG), thermoplastic polyurethane (TPU), polypropylene, and polycarbonate1,2. PETG is a commonly preferred material for CAs because of its higher translucency, fatigue resistance, and dimensional stability2. TPU is a ductile elastomer with high elasticity and formability, which provides good wearability and shock absorption3,4. In addition, multi-layer hybrid materials have been introduced to overcome the drawbacks of single-layer materials. Materials with a combination of hard outer shells and a soft inner shell show improved mechanical strength of maximum load in the tensile test and water absorption rate5.

The clinical performance of CAs has been enhanced by development new materials with good mechanical properties. However, the conventional fabrication process, which involves vacuum thermoforming of thermoplastic materials, is both time- and labor-intensive for producing serial models and trimming the aligners along the gingival margin at each stage6,7. This process also has adverse environmental effects, such as plastic waste and energy consumption8. In addition, the thermoforming process may result in unpredictable changes in physical properties of the CAs, making it difficult to predict its treatment outcomes6,7. Varying degrees of shrinkage and expansion are observed in thermoplastic materials after the thermoforming process9, which can affect the thickness and fit of aligners. A previous study that evaluated the thickness and gap width of CAs after the manufacturing process found variations in these parameters for all thermoplastic materials depending on tooth type and location, such as the incisor, canine, and molar teeth or buccal and palatal sides10.

The thickness and gap width of CAs are clinically important factors for increasing the predictability of their performance11. The thickness of CAs can affect the forces and moments needed for tooth movement11,12,13. The close fit between tooth surfaces and CAs is an crucial factor in allowing effective force to be transferred to the teeth and plays an effective role in anchorage10,14. As patients seeking orthodontic treatment often prioritize esthetic features, including color stability and translucency, the translucency is also considered a significant clinical factor15,16.

With the development of three dimensional (3D) printers and their materials, CAs have begun to be integrated with digital technologies. Advances in technology allow clinicians to take intraoral scans, set up the virtual tooth movement, and directly produce CAs using a 3D printer without taking impressions or using plaster models17, minimizing the cumulative errors from the thermoplastic workflows6. In addition, 3D printing is associated with shorter manufacturing time and high efficiency when producing a series of aligners simultaneously18, lower costs and efforts, and less waste material and environmental pollution17,19. As a result, the application of CAs has expanded, and their fabrication reproducibility has improved17.

Currently, several research methodologies for evaluating the accuracy of CAs are being studied. Cole et al. found that the dimensional accuracy of thermoformed and 3D-printed CAs evaluated using scanning and superimposition techniques with geometric software at specific tooth landmarks ranged from 0.1 to 0.3 mm and from 0.1 to 0.4 mm, respectively20. Jindal et al. also found that the geometrical accuracy of thermoformed and 3D-printed CAs, in terms of tooth height, ranged between 0–0.88 mm and 0.02–0.86 mm, respectively6. Although these results were concluded to be clinically acceptable, the dimensional accuracy of CAs shows a wide range. In addition, spray application is required to scan the highly reflective or transparent surface of the CAs with the above method, which may affect accuracy21. Meanwhile, comparing the dimensional accuracy of the aligners fitted to the models using micro computed tomography (micro-CT) scanning is advantageous because the technique is non-invasive and precise10,22. Lombardo et al. attempted to evaluate the thickness and gap width of aligners using cone-beam computed tomography10. However, their study was limited to examining only thermoformed materials and performing repeated measurements of a single sample.

Furthermore, the post-processing step is crucial to enhance the printing accuracy of the 3D-printed CAs23,24. 3D-printed CAs require post-processing immediately after printing25, and this typically involves three steps: support removal, cleaning, and post-curing26. Different cleaning methods to remove any uncured resin residue from 3D-printed CAs are recommended by manufacturers depending on the material, and it can also have an impact on the surface roughness and mechanical properties of the manufactured aligners23,24. The most commonly used solvent to remove excess uncured resin from aligners is isopropyl alcohol (IPA), which effectively dissolves esters27. Nevertheless, IPA should be used as a solvent with caution due to its high volatility and flammability, that can lead to respiratory problems with prolonged exposure28.

Recently, resin materials for 3D-printed CAs with good mechanical, optical, and biocompatible properties have been developed29. The development of photo-polymerizable polyurethane (Tera Harz TC-85, Graphy Inc., Seoul, Korea) has received approval from the Korea and United States Food and Drug Administration for biocompatibility30. TC-85 has viscous and flexible characteristics, which can continuously apply light forces on the teeth and exhibits creep behavior31. Additionally, it has shape-memory properties and dimensional stability at high temperatures31. The manufacturing company of TC-85 recommends a non-chemical cleaning method called centrifugation as an alternative to IPA32. However, the effect of different cleaning methods on the translucency, thickness, and gap width in the post-processing of the TC-85 3D-printed CAs has not yet been tested.

Therefore, the present study evaluated the null hypothesis that different fabrication protocols have no significant effects on the translucency, thickness, and gap width of CAs. The specific objectives of this study were to evaluate the micro-level variations in thickness and gap width between different tooth types and locations.

The translucency values were significantly higher in the TS, TM, and PC groups than in the PA group (p < 0.01) (Table 1).

There were significant differences in thickness and gap width among the four groups (p < 0.01). The median thicknesses of the TS, TM, PA, and PC groups were 504.68 μm, 509.54 μm, 614.24 μm, and 687.53 μm, respectively. The median gap widths of the TS, TM, PA, and PC groups were 69.80 μm, 52.35 μm, 69.80 μm, and 69.80 μm, respectively. The median thickness was significantly higher in the PC group compared to the other groups (p < 0.01). The median gap width was significantly higher in the PA, PC groups than in the TM group (p < 0.01) (Table 2).

In the TS, PA, and PC groups, the median thickness was greater for the anterior teeth than for the posterior teeth (TS: p < 0.05; PA and PC: p < 0.01).

Group variations in the median thickness were observed as follows: TS: buccogingival < buccal < palatogingival < palatal < incisal or occlusal; TM: buccogingival < buccal < palatogingival < palatal, incisal or occlusal; and PA, PC: buccal, palatogingival, buccogingival < palatal < incisal or occlusal. The thickness variations are further detailed in Table 3 and Fig. 1A,C.

Median (IQR) thickness and gap width for four clear aligners according to tooth type and location. (A) and (C), median thickness by tooth type and location; (B) and (D), median gap width by tooth type and location. Outlier (1.5 × IQR) values are shown by closed circles. Pg: palatogingival; Pa: palatal; In/Oc: incisal or occlusal; Bu: buccal; Bg: buccogingival.

In the TM group, the median gap width was greater for the anterior teeth than for the posterior teeth (p < 0.05), while the median gap width for the anterior and posterior teeth were similar in the other groups.

Group variations in the median gap width were observed as follows: TS: buccal, buccogingival < palatal, palatogingival, incisal or occlusal; TM: buccal, buccogingival < palatal, incisal or occlusal, palatogingival; PA: palatal < buccal, incisal or occlusal < palatogingival, buccogingival; and PC: buccal, incisal or occlusal < palatal, buccogingival, palatogingival. The gap width variations are further detailed in Table 4 and Fig. 1B,D. The four clear aligner groups showed differences in 3D-distribution of the gap along the central incisor (Fig. 2).

Representative images of the three-dimensional distribution of the gap along the central incisor with different group of clear aligners. The color scale represents the amount of the gap from 0 to 200 µm (yellow to red). The blank (empty) region within the tooth outline represents areas with negligible gap.

Transparency is the physical property that allows light to pass through a material, which is an important factor in determining the esthetics of the CAs and is the major concern of individuals seeking orthodontic treatment15,16. The thickness and gap width of CAs are also important factors that can have the greatest influence on orthodontic treatment10,12,14. The thickness of CAs can be used as a predictive factor by orthodontist to control the physiological forces and moments applied to the teeth during treatment33. During orthodontic treatment, the physiological forces applied to the teeth enable resorptive remodeling and controlled tooth movement34,35. However, overloading the teeth with excessive forces can result in side effects, such as cell death, tissue hyalinization of the periodontal ligament, alveolar bone necrosis, and external root resorption36. The inner surface of the aligner must be as close to the teeth as possible to provide a clinically effective force10. Moreover, a reduced fit can cause aligners to lift up during the torquing process of root movements, making it difficult to establish an effective force couple37.

In addition, the post-processing procedure is a crucial step as it can affect the printing accuracy and mechanical properties of the printed objects23,24. However, there is insufficient evidence-based data to evaluate the changes in the translucency, thickness, and gap width of TC-85 3D-printed CAs according to different cleaning methods. Therefore, this study used IPA and centrifugation as the two chemical and non-chemical cleaning methods for evaluating the outcomes of the 3D-printed samples.

Thermoformed CAs made from thermoplastic materials could be worn immediately on the teeth. However, 3D-printed CAs developed using the TC-85 material required a clinically different wearing protocol, as recommended by the manufacturer due to their special properties, which was applied in this study. Based on the geometric stability at high temperatures and shape-memory property of TC-85, 3D-printed CAs were immersed in 80 °C water, which is higher than the glass transition temperature31. This immersion was performed to increase flexibility of the aligners before placing them on the models31. Afterward, the sample gradually recovered its original shape and fit when kept at a temperature of 37 °C, indicating that the deformation was reversible31. In summary, the softening of aligners by warm water provided the comfortable wear to the models. Thereafter, the samples were dried at a temperature of 37 °C to recover their original shape and strength.

There were differences in translucency among the CAs manufactured by different fabrication protocols. The PC group showed significantly higher translucency, similar to that of the TS and TM groups. On the other hand, the PA group showed a decrease in translucency. IPA is the most commonly used solvent for dissolving excess uncured resin27. However, previous studies have suggested that IPA, due to low compatibility with acrylate based polymer, tends to cause polymer swelling instead of dissolution38,39. Furthermore, as IPA evaporates from the swollen polymer surface, the polymer chains can undergo reorganization, resulting in changes in the surface’s solubility and leading to surface cracking of the 3D-printe objects39. Therefore, it could be inferred that IPA cleaning has a negative effect on the surface properties of the TC-85 3D-printed CAs.

Further, the findings of our study demonstrated that the thermoformed CAs decreased in thickness after the fabrication process, while the 3D-printed CAs increased in thickness compared to their set-up thickness. While an increase in overall thickness was observed in the PC group compared to the PA group, there was no significant difference in thickness after the thermoforming process of the TS and TM groups. In previous studies, it has been shown that thermoplastic materials experience a decrease in thickness during the thermoforming process, while 3D-printed aligners undergo an increase in thickness13,31. Lee et al. reported a 54.7% decrease in the thickness of PETG samples thermoformed on a standardized maxillary incisor model31. Edelmann et al. found that the 3D-printed CAs increase in thickness by approximately 0.2 mm after printing21.

Significant differences in thickness for each tooth type were observed among the CAs manufactured by different fabrication protocols. The TS group was less stretched at the anterior teeth than at the posterior teeth under heat and pressure. The PA and PC groups showed thicker output in the anterior teeth compared to the posterior teeth. The reason for the thickening of the anterior teeth in the 3D-printed groups is as follows: the anterior teeth are structurally tapered and have longer crowns. It is difficult to remove any uncured resin remaining on the inner surface before the final post-polymerization step6, which may cause an increase in thickness. When observing thickness variations according to tooth location, the TS and TM groups were thinner at the buccal and buccogingival areas. Thermoplastic materials showed a greater thickness reduction in the convex buccal surface and distant gingival areas as they wrapped and extended from the occlusal surface of the model. Further, the median thickness of the incisal/occlusal areas in the PA and PC groups was significantly greater than that in other locations. This appeared to be a printing error owing to the complex curvature of the tooth surface at the incisal edge, occlusal cusp tip, and occlusal central pit. This printing error can occur in the curved contour area during thickness layering, which is affected by the layer thickness, curvature radius, and inclination40.

In the present study, the TM group showed the least gap width amongst the groups. The multi-layer hybrid material consisted of copolyesters and a flexible elastomer core, which has better mechanical strength with a higher maximum load in the tensile test than a single-layer material5. Therefore, a multi-layer material might be more extensible during heating and pressure, resulting in a better fit. Different patterns of gap width depending on the tooth location between thermoformed and 3D-printed CAs were also observed. In the thermoformed groups, the incisal/occlusal surface showed the greatest thickness with less variation, but had the largest gap width. In the 3D-printed groups, the buccal side showed the least thickness and variation with a small gap width, whereas the incisal/occlusal surface demonstrated the greatest variation in thickness, resulting in the thickest aligner, but with the smallest gap width. However, the gingival areas on both sides had less thickness variation and showed the largest gap width in the 3D-printed CAs. This phenomenon occurs due to the accumulation of polymerization shrinkage during the printing process, that magnifies the unsuitability of the gingival margins41.

Based on previous studies, various parameter optimizations were performed to improve 3D printing accuracy in this study. Firstly, the post-curing process for 3D-printed CAs was performed under nitrogen conditions that prevented the formation of an oxygen inhibition layer, allowing the surface of the specimen to polymerize42,43. Injecting inert nitrogen gas to exclude oxygen can also help to achieve good mechanical properties and surface smoothness of the 3D-printed CAs43. Secondly, the build angle and layer thickness are particularly important settings for the accuracy of 3D printing. As a result, the 3D-printed CAs were designed at a build angle of 30° and printed using a digital light processing (DLP) 3D printer with a 50 µm resolution, based on previous studies44,45. Thirdly, a 50 µm offset was applied to the inner surface of the 3D-printed CAs to compensate for the thickness change and to enhance the adaptability46. A previous study examining the fit of a printed splint showed that splints with 0.05, 0.1, and 0.2 mm offsets can fit the teeth better than those without offset46. In addition, the dimensional accuracy of a 3D-printed aligners is affected by factors including light intensity, exposure time, and the properties of printing materials such as light-blocking pigment concentration and light penetration44,47,48. Therefore, it is important to calibrate printing parameters to enhance the printing accuracy and minimize variance in each output49.

Though the present study presented an objective assessment of differences among four CAs groups, the findings should be interpreted within the limitations. Although it is theoretically possible to set the thickness of 3D-printed CAs for comparison with thermoformed aligners, the recommendations for effective TC-85 3D-printed aligners have a lower limit of 0.5 mm. Therefore, the sample selection criteria were based on clinically recommended preferences. Taking the above into account, we selected a thickness of 0.75 mm (factoring in thickness reduction) for the thermoplastic materials and a thickness of 0.5 mm for our 3D-printed CAs, which is the optimal thickness currently applied in clinical practice. Even though the wearing protocol recommended by the manufacturer was followed to apply the 3D-printed CAs to the models, there were experimental constraints in creating an oral environment at 37 °C temperature with high relative humidity during micro-CT scanning, which may have affected the fit. The present study used only passive-state CAs with a normal occlusion model to obtain objective evaluation data on 3D-printed CAs, as there is no information on how 3D-printed CAs are manufactured and printed depending on tooth type and location. In the future, it will be important to observe differences in thickness and gap width when CAs are activated in various degrees of malocclusion, and to evaluate how attachments affect the thickness and gap width of the aligners. Furthermore, additional evaluation is needed to determine how the thickness and gap width observed in this study affect the clinical performance of achieving the desired tooth movement.

Our null hypothesis that there is no difference in translucency, thickness, and gap width among groups manufactured by different fabrication protocols was rejected in this study. After the manufacturing process, the thermoformed CAs showed a reduction in thickness while the 3D-printed CAs showed an increase in thickness. The PA group showed the lowest translucency, and the TM group had the best fit amongst the groups. The thickness and regions of best fit of the thermoformed and 3D-printed CAs significantly varied depending on the tooth type and location. Additionally, the cleaning methods used in the post-processing of 3D-printed CAs affected their translucency and thickness.

A standardized model of the maxillary dental arch in Korean adults with normal occlusion (CON2001-UL-SP-FEM-32, Nissin Dental, Kyoto, Japan) was used and scanned using an intraoral scanner (D250, 3shape, Copenhagen, Denmark) to create an STL file. A standardized model of 60 mm × 50 mm × 20 mm was then printed (S-100, Graphy Inc., Seoul, Korea) using a DLP 3D printer (Asiga MAX™, Asiga, Alexandria, Australia).

Ten CA samples were prepared for each group. Thermoformed CAs were divided into a single-layer group (TS group) with a PETG sheet (Duran, Scheu-Dental, Iserlohn, Germany) and a multi-layer group (TM group) with copolyester in both outer shells and thermoplastic elastomer in the inner shell sheet (CA pro, Scheu-Dental, Iserlohn, Germany). According to the cleaning method, 3D-printed CAs with photo-polymerizable polyurethane resin (TC-85) were divided into two groups: a PA group with isopropyl alcohol cleaning and a PC group with centrifuge cleaning.

A 0.75-mm-thick thermoplastic material was vacuum-thermoformed on a standardized model using a thermomolding caster (Biostar, Scheu-Dental, Iserlohn, Germany) under the thermal deformation conditions recommended by the manufacturer. The thickness of the CAs may be affected by various conditions, such as model preparation, pressure, heat, and positioning of the model on the platform. Therefore, it is important to control these conditions as much as possible during manufacturing22,50. A uniform base was created by setting a constant height of the model from the teeth, and the model was placed at the center of the platform, such that the mid-palatal suture was oriented toward the 12 o'clock position. The orientation of the model was kept constant based on the markings for each thermoforming process. As the final step, the CAs were separated from the model and the gingival edge of the aligner was cut and polished.

3D-printed CAs were designed using computer-assisted design software (Deltaface, Coruo, Limoges, France) with a set up thickness of 0.5 mm, offset of 50 μm, and positioned at 30° as a print angulation with minimum strut supports. A DLP 3D printer (SprintRay Pro 95, SprintRay, Los Angeles, CA) was used with a layer thickness of 50 μm. Two different cleaning methods were used to remove any uncured resin from the aligner surfaces. CAs were cleaned either for 1 min with 99.5% IPA or for 6 min and 500 rpm using a centrifuge. The samples were then cured twice for 25 min under nitrogen conditions with ultraviolet light (385–405 nm) using a post-curing chamber (CureM U102H, Graphy Inc., Seoul, Korea). Final cleaning was performed with flowing water and using an ultrasonic cleaner for 3 min at 76–80 °C. The diagram presented in Fig. 3 shows the experimental design.

Flowchart of experimental design.

The thermoformed CAs were immediately fitted onto the standardized model at room temperature, whereas the 3D-printed CAs were inserted after being smoothly transformed in warm water at 80 °C, following the manufacturer's clinical protocol. Afterwards, the 3D-printed samples were dried at 37 °C to restore their original shape and strength. All aligners (n = 10) were scanned using a high-resolution micro-CT (Skyscan1173, Bruker, MA, USA) at 40 kV, 200 μA, and 34.9 μm of resolution. A total of 40 micro-CTs were obtained, and the target areas of dentition (anterior teeth: the right maxillary central incisor, canine; posterior teeth: the right maxillary first premolar and molar) were re-orientated using Dataviewer software (version 1.5.6.2, Bruker, MA, USA). Slices were obtained using a horizontal plane from the model base and perpendicular to the middle of the line linking the most mesial and distal contact points of the tooth, and were saved by applying the volume of interest (VOI). The images were analyzed using CTAn software (release 2.5, Bruker, MA, USA) at 300× magnification (Fig. 4). Thereafter, the shortest distance of thickness and gap width were measured by projecting a perpendicular line from each reference point tangent. These 5–7 reference points were based on a pilot study and included gingival margins, buccal and palatal midpoints, and incisal/occlusal points (incisal edge, occlusal cusp tips, and central pit) (Fig. 5)51. The occlusal surface of the molars includes both the cusp tips and central pit structures, but they are clinically considered as a single plane. Therefore, instead of separating and analyzing their measurement values individually (\({{Oc}_{1},{Oc}_{2},Oc}_{3}\)), we interpreted them through mean values. A total of 960 points on tooth surfaces were included in the measurements, which were repeated twice at an interval of two weeks by one researcher.

The measurement method of thickness and gap width using micro-CT. (A) A clear aligner was placed on a standardized model; (B) and (C) the slice plane setting of the target tooth obtained from micro-CT imaging and the application of VOI were performed using Dataviewer software; and (D) the thickness and gap width of the tooth were measured using CTAn software.

Microphotographs showing the thickness and gap width between aligners and teeth at reference points (tooth location). (A) anterior teeth (e.g., the central incisor); (B) posterior teeth (e.g., the first premolar). Yellow arrows show the reference points of teeth; Pg, palatogingival; Pa, palatal; In/Oc, incisal or occlusal; Bu, buccal; Bg, buccogingival.

Translucency is the difference in the color of a material with a uniform thickness over white and black backgrounds52. A spectrophotometer (CM-3500d, Konica Minolta, Tokyo, Japan) was used to calculate the CIELab coordinates of the specimens placed on white and black backgrounds. The window size of the spectrophotometer was 3 mm, and 10 samples with a 3 mm diameter of 0.75-mm-thick thermoformed and 0.5-mm-thick 3D-printed specimens were prepared. The following Eq. (1) was used to determine translucency:

Translucency parameter ranged from 0 (complete opacity) to 100 (complete transparency)53.

Using 3D Slicer software (version 5.0.3, http://www.slicer.org), the micro-CT Digital Imaging and Communications in Medicine (DICOM) files of the central incisors were analyzed. Manual segmentation was performed to obtain the 3D information of the gap between the tooth and the aligners. The manually segmented regions of interest were 3D-rendered and exported as STL files. The STL files representing the gap width between the tooth and aligners were morphometrically compared using Geomagic Control X software (version 2018.0.1, 3D Systems, SC, USA).

SPSS software (version 25.0, IBM, NY, USA) was used for statistical analysis of the data. The Shapiro–Wilk test for normality was applied, and the normality of the distribution was rejected. A non-parametric Mann–Whitney U test and Kruskal–Wallis test were performed to compare the median translucency, thickness, and gap width of aligners depending on tooth type and location, followed by Mann–Whitney test with Bonferroni’s correction for multiple comparisons. The p-value for statistical significance (conventional level of 0.05) was divided by the number of statistical tests performed.

All of the data supporting this work will be made available from the corresponding author upon reasonable request.

Zhang, N., Bai, Y., Ding, X. & Zhang, Y. Preparation and characterization of thermoplastic materials for invisible orthodontics. Dent. Mater. J. 30, 954–959 (2011).

Article CAS PubMed Google Scholar

Dupaix, R. B. & Boyce, M. C. Finite strain behavior of poly(ethylene terephthalate) (PET) and poly(ethylene terephthalate)-glycol (PETG). Polymer 46, 4827–4838 (2005).

Article CAS Google Scholar

Lu, Q. W. & Macosko, C. W. Comparing the compatibility of various functionalized polypropylenes with thermoplastic polyurethane (TPU). Polymer 45, 1981–1991 (2004).

Article CAS Google Scholar

Hu, B., Li, M., Jiang, J. & Zhai, W. Development of microcellular thermoplastic polyurethane honeycombs with tailored elasticity and energy absorption via CO2 foaming. Int. J. Mech. Sci. 197, 106324 (2021).

Article Google Scholar

Ahn, H. W., Kim, K. A. & Kim, S. H. A new type of clear orthodontic retainer incorporating multi-layer hybrid materials. Korean J. Orthod. 45, 268–272 (2015).

Article PubMed PubMed Central Google Scholar

Jindal, P., Juneja, M., Siena, F. L., Bajaj, D. & Breedon, P. Mechanical and geometric properties of thermoformed and 3D printed clear dental aligners. Am. J. Orthod. Dentofac. Orthop. 156, 694–701 (2019).

Article Google Scholar

Ryu, J. H., Kwon, J. S., Jiang, H. B., Cha, J. Y. & Kim, K. M. Effects of thermoforming on the physical and mechanical properties of thermoplastic materials for transparent orthodontic aligners. Korean J. Orthod. 48, 316–325 (2018).

Article PubMed PubMed Central Google Scholar

Hartshorne, J. & Wertheimer, M. Emerging insights and new developments in clear aligner therapy (CAT)—A review of the literature. Am. J. Orthod. Dentofac. Orthop. Clin. Companion 2, 311–324 (2022).

Google Scholar

Johal, A., Sharma, N. R., McLaughlin, K. & Zou, L. F. The reliability of thermoform retainers: A laboratory-based comparative study. Eur. J. Orthod. 37, 503–507 (2014).

Article PubMed Google Scholar

Lombardo, L. et al. MicroCT X-ray comparison of aligner gap and thickness of six brands of aligners: An in-vitro study. Prog. Orthod. 21, 1–12 (2020).

Article Google Scholar

Barone, S., Paoli, A., Neri, P., Razionale, A. V. & Giannese, M. Mechanical and geometrical properties assessment of thermoplastic materials for biomedical application. Adv. Mech. Des. Eng. Manuf. 14–16, 437–445 (2017).

Google Scholar

Gao, L. & Wichelhaus, A. Forces and moments delivered by the PET-G aligner to a maxillary central incisor for palatal tipping and intrusion. Angle Orthod. 87, 534–541 (2017).

Article PubMed PubMed Central Google Scholar

Min, S., Hwang, C. J., Yu, H. S., Lee, S. B. & Cha, J. Y. The effect of thickness and deflection of orthodontic thermoplastic materials on its mechanical properties. Korean J. Orthod. 40, 16–26 (2010).

Article Google Scholar

Mantovani, E. et al. Scanning electron microscopy evaluation of aligner fit on teeth. Angle Orthod. 88, 596–601 (2018).

Article PubMed PubMed Central Google Scholar

Bichu, Y. M. et al. Advances in orthodontic clear aligner materials. Bioactive Mater. 22, 384–403 (2023).

Article Google Scholar

Macri, M., Murmura, G., Varvara, G., Traini, T. & Festa, F. Clinical performances and biological features of clear aligners materials in orthodontics. Front. Mater. 9, 819121 (2022).

Article Google Scholar

Tartaglia, G. M. et al. Direct 3D printing of clear orthodontic aligners: Current state and future possibilities. Materials 14, 1799 (2021).

Article ADS CAS PubMed PubMed Central Google Scholar

Yu, X. et al. ‘Invisible’ orthodontics by polymeric ‘clear’ aligners molded on 3D-printed personalized dental models. Regener. Biomater. 9, rbac007 (2022).

Article CAS Google Scholar

Peeters, B., Kiratli, N. & Semeijn, J. A barrier analysis for distributed recycling of 3D printing waste: Taking the maker movement perspective. J. Clean. Prod. 241, 118313 (2019).

Article Google Scholar

Cole, D., Bencharit, S., Carrico, C. K., Arias, A. & Tufekci, E. Evaluation of fit for 3D-printed retainers compared with thermoform retainers. Am. J. Orthod. Dentofac. Orthop. 155, 592–599 (2019).

Article Google Scholar

Edelmann, A., English, J. D., Chen, S. J. & Kasper, F. K. Analysis of the thickness of 3-dimensional-printed orthodontic aligners. Am. J. Orthod. Dentofac. Orthop. 158, E91-98 (2020).

Article Google Scholar

Ammann, R. et al. Three-dimensional analysis of aligner gaps and thickness distributions, using hard x-ray tomography with micrometer resolution. J. Med. Imaging 9, 031509 (2022).

Article Google Scholar

Piedra Cascón, W., Krishnamurthy, V. R., Att, W. & Revilla León, M. 3D printing parameters, supporting structures, slicing, and post-processing procedures of vat-polymerization additive manufacturing technologies: A narrative review. J. Dent. 109, 103630 (2021).

Article PubMed Google Scholar

Mostafavi, D., Methani, M. M., Piedra Cascón, W., Zandinejad, A. & Revilla León, M. Influence of the rinsing postprocessing procedures on the manufacturing accuracy of vat-polymerized dental model material. J. Prosthodontics 30, 610–616 (2021).

Article Google Scholar

Kasper, F. K. 3D printing applications in clear aligner fabrication. Embracing Novel Technol. Dent. Orthodon. 56, 7–21 (2020).

Google Scholar

Jang, W. H. et al. Effect of washing condition on the fracture strength, and the degree of conversion of 3D printing resin. Appl. Sci. 11, 11676 (2021).

Article CAS Google Scholar

Krechmer, J. E. et al. Chemical emissions from cured and uncured 3D-printed ventilator patient circuit medical parts. ACS Omega 6, 30726–30733 (2021).

Article CAS PubMed PubMed Central Google Scholar

David, E. & Niculescu, V. C. Volatile organic compounds (VOCs) as environmental pollutants: Occurrence and mitigation using nanomaterials. Int. J. Environ. Res. Public Health 18, 13147 (2021).

Article CAS PubMed PubMed Central Google Scholar

Nakano, H. et al. Development of biocompatible resins for 3D printing of direct aligners. J. Photopolym. Sci. Technol. 32, 209–216 (2019).

Article CAS Google Scholar

Rajasekaran, A. & Chaudhari, P. K. Integrated manufacturing of direct 3D-printed clear aligners. Front. Dent. Med. https://doi.org/10.3389/fdmed.2022.1089627 (2023).

Article Google Scholar

Lee, S. Y. et al. Thermo-mechanical properties of 3D printed photocurable shape memory resin for clear aligners. Sci. Rep. 12, 6246 (2022).

Article ADS CAS PubMed PubMed Central Google Scholar

Zinelis, S., Panayi, N., Polychronis, G., Papageorgiou, S. N. & Eliades, T. Comparative analysis of mechanical properties of orthodontic aligners produced by different contemporary 3D printers. Orthod. Craniofac. Res. 25, 336–341 (2022).

Article PubMed Google Scholar

Elkholy, F., Schmidt, F., Jäger, R. & Lapatki, B. G. Forces and moments delivered by novel, thinner PET-G aligners during labiopalatal bodily movement of a maxillary central incisor: An in vitro study. Angle Orthod. 86, 883–890 (2016).

Article PubMed PubMed Central Google Scholar

Masella, R. S. & Meister, M. Current concepts in the biology of orthodontic tooth movement. Am. J. Orthodon. Dentofac. Orthop. 129, 458–468 (2006).

Article Google Scholar

Sprogar, Š, Vaupotic, T., Cör, A., Drevenšek, M. & Drevenšek, G. The endothelin system mediates bone modeling in the late stage of orthodontic tooth movement in rats. Bone 43, 740–747 (2008).

Article CAS PubMed Google Scholar

Feller, L. et al. Biological events in periodontal ligament and alveolar bone associated with application of orthodontic forces. Sci. World J. 2015 (2015).

Hahn, W. et al. Torquing an upper central incisor with aligners-acting forces and biomechanical principles. Eur. J. Orthod. 32, 607–613 (2010).

Article PubMed Google Scholar

Bardelcik, A., Yang, S., Alderson, F. & Gadsden, A. The effect of wash treatment on the mechanical properties and energy absorption potential of a 3D printed polymethyl methacrylate (PMMA). Mater. Today Commun. 26, 101728 (2021).

Article CAS Google Scholar

Andrews, E., Levy, G. & Willis, J. Environmental crazing in a glassy polymer: The role of solvent absorption. J. Mater. Sci. 8, 1000–1008 (1973).

Article ADS CAS Google Scholar

Lianghua, Z. Process analysis and experimental research of 3D printing with variable parameters. J. Phys. Conf. Ser. 1676, 012163 (2020).

Article Google Scholar

Yang, M. S., Kim, S. K., Heo, S. J., Koak, J. Y. & Park, J. M. Investigation of the marginal fit of a 3D-printed three-unit resin prosthesis with different build orientations and layer thicknesses. J. Adv. Prosthodontics 14, 250–261 (2022).

Article Google Scholar

Gojzewski, H. et al. Layer-by-layer printing of photopolymers in 3D: How weak is the interface?. ACS Appl. Mater. Interfaces. 12, 8908–8914 (2020).

Article CAS PubMed PubMed Central Google Scholar

Reymus, M., Lümkemann, N. & Stawarczyk, B. 3D-printed material for temporary restorations: Impact of print layer thickness and post-curing method on degree of conversion. Int. J. Comput. Dent. 22, 231–237 (2019).

PubMed Google Scholar

Zhang, Z. C., Li, P. L., Chu, F. T. & Shen, G. Influence of the three-dimensional printing technique and printing layer thickness on model accuracy. J. Orofac. Orthop./Fortschritte der Kieferorthopädie 80, 194–204 (2019).

Article PubMed Google Scholar

Ko, J. et al. Effect of build angle and layer height on the accuracy of 3-dimensional printed dental models. Am. J. Orthod. Dentofac. Orthop. 160, 451–458 (2021).

Article Google Scholar

Ye, N. et al. Precision of 3D-printed splints with different dental model offsets. Am. J. Orthod. Dentofac. Orthop. 155, 733–738 (2019).

Article Google Scholar

Favero, C. S. et al. Effect of print layer height and printer type on the accuracy of 3-dimensional printed orthodontic models. Am. J. Orthod. Dentofac. Orthop. 152, 557–565 (2017).

Article Google Scholar

Seo, J. W., Kim, G. M., Choi, Y., Cha, J. M. & Bae, H. Improving printability of digital-light-processing 3D bioprinting via photoabsorber pigment adjustment. Appl. Sci. 23, 5428 (2022).

CAS Google Scholar

Mukherjee, E., Malone, L., Tackett, E., Gunaratnam, B. & Grant, G. T. Monitoring the calibration of in-office 3D printers. Dent. J. 11, 20 (2023).

Article Google Scholar

Ihssen, B. A., Kerberger, R., Rauch, N., Drescher, D. & Becker, K. J. A. S. Impact of dental model height on thermoformed PET-G aligner thickness—An in vitro micro-CT study. Appl. Sci. 11, 6674 (2021).

Article CAS Google Scholar

Palone, M. et al. Micro-computed tomography evaluation of general trends in aligner thickness and gap width after thermoforming procedures involving six commercial clear aligners: An in vitro study. Korean J. Orthodon. 51, 135–141 (2021).

Article Google Scholar

O’Brien, W. J., Boenke, K. M. & Groh, C. L. Coverage errors of two shade guides. Int. J. Prosthodont. 4, 45–50 (1991).

PubMed Google Scholar

Abdelbary, O., Wahsh, M., Sherif, A. & Salah, T. Effect of accelerated aging on translucency of monolithic zirconia. Future Dent. J. 2, 65–69 (2016).

Article Google Scholar

Download references

The study was supported by a faculty research grant of Yonsei University College of Dentistry for 6-2022-0009.

Department of Orthodontics, College of Dentistry, Yonsei University, Seoul, South Korea

So Yeon Park

Department of Orthodontics, Institute of Craniofacial Deformity, College of Dentistry, Institute for Innovation in Digital Healthcare, Yonsei University, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, South Korea

Sung-Hwan Choi, Hyung-Seog Yu & Jung-Yul Cha

Department of Orthodontics, Kyung Hee University School of Dentistry, Seoul, South Korea

Su-Jung Kim

Laboratory of Adhesion & Bio-Composites, Forestry and Bioresources, Seoul National University, Seoul, South Korea

Hoon Kim

Department of Orthodontics, Saint Louis University, Saint Louis, MO, USA

Ki Beom Kim

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

You can also search for this author in PubMed Google Scholar

S.Y.P. and J.Y.C. designed the experiments and analyzed the data. S.Y.P. performed all the experiments and wrote the manuscript. S.H.C., H.S.Y., S.J.K., H.K., K.B.K. and J.Y.C. provided manuscript writing assistance and critically revised the manuscript for important intellectual content. All authors reviewed and approved the final manuscript.

Correspondence to Jung-Yul Cha.

The authors declare no competing interests.

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and Permissions

Park, S.Y., Choi, SH., Yu, HS. et al. Comparison of translucency, thickness, and gap width of thermoformed and 3D-printed clear aligners using micro-CT and spectrophotometer. Sci Rep 13, 10921 (2023). https://doi.org/10.1038/s41598-023-36851-5

Download citation

Received: 25 January 2023

Accepted: 11 June 2023

Published: 05 July 2023

DOI: https://doi.org/10.1038/s41598-023-36851-5

Anyone you share the following link with will be able to read this content:

Sorry, a shareable link is not currently available for this article.

Provided by the Springer Nature SharedIt content-sharing initiative

By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.